BTZJC - AEROSOL SPRAY PAINTS, 1253409

  • MSDS: BTZJC
  • Manufacturer: M A BRUDER AND SONS INC
  • Product Name: AEROSOL SPRAY PAINTS, 1253409
  • National Stock Number: 8010-00N049718
Product Identification

Product ID:AEROSOL SPRAY PAINTS, 1253409
MSDS Date:07/21/1989
FSC:8010
NIIN:00N049718
MSDS Number: BTZJC

Responsible Party
M A BRUDER & SONS INC
630 N THIRD ST
TERRE HAUTE, IN 47806-1508
US

Emergency Phone: 812-234-6621

Info Phone: 812-234-6621

Cage: 1Y265

Contractor
M A BRUDER & SONS INC
TERRE HAUTE, IN 47806-1508 US

Telephone: 812-234-6621

Cage: 1Y265

Ingredients

36.7 @ 20C.

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUIDINE PIGMENT

OSHA PEL N/K

ACGIH TLV: N/K


VM&P NAPHTHA; (ALIPHATIC HYDROCARBON)

CAS: 64742-89-8

OSHA PEL 300 PPM;400 STEL

ACGIH TLV: 300 PPM


25 @ 20C.

CAS: 1330-20-7

RTECS: ZE2100000

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM;150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LUNG, LIVER,

RTECS: 9999999ZZ


EFTS SUCH AS TEMPORARY MUSCULAR WEAK & LOSS

RTECS: 9999999ZZ


CAN BE ABSORBED

RTECS: 9999999ZZ


CARBOXYHEMOGLOBIN LEVELS OF OXYGEN IN BLOOD. HEAVY

RTECS: 9999999ZZ


HEART PROBS. HAS SHOWN MUTAGENIC ACTIVITY.

RTECS: 9999999ZZ


EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT

RTECS: 9999999ZZ


CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN

RTECS: 9999999ZZ


TOLUENE APPEARS ON NAVY LIST OF OCCUP CHEM

RTECS: 9999999ZZ


PROFESSIONALS CONCERNING LATEST HAZ LIST INFO & SAFE

RTECS: 9999999ZZ


MAY CAUSE THE FORMATION OF HCL &/OR PHOSGENE .

RTECS: 9999999ZZ


SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (AROMATIC

CAS: 64742-95-6

RTECS: WF3400000

OSHA PEL 25 PPM (MFR)

ACGIH TLV: 25 PPM (MFR)


ARIEN; (HYDROCARBON RESIN)

CAS: 64742-16-1

RTECS: CF2550000

OSHA PEL N/K

ACGIH TLV: N/K


PROPANE; (LIQUIFIED COMPRESSED GAS)

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


MINERAL SPIRITS; (MEDIUM MINERAL SPIRITS)

CAS: 64742-88-7

OSHA PEL N/K

ACGIH TLV: N/K


METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA III).

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


NONHAZARDOUS INGREDIENTS; (NON-HAZARDOUS POLYMER)

OSHA PEL N/K

ACGIH TLV: N/K


PYRAZOLONE ORANGE

CAS: 15793-73-4

OSHA PEL N/K

ACGIH TLV: N/K


SILICONE RESIN

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INGEST:GI DISTRESS. INHAL:OVEREXP MAY
CAUSE NOSE & THROAT IRRIT. MAY CAUSE CNS EFTS SUCH AS DIZZ, HDCH,
NAUS, STAG GAIT, CONFUSN & UNCON. RPTS HAVE ASSOC RPTD & PRLNG
OVEREXP TO SOLVS W/PERM BRAIN & N ERV SYS DMG, EYE WATERING, HDCHS,
NAUS,DIZZ & LOSS OF COORD ARE SIGNS THAT SOLV LEVELS ARE TOO HIGH.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONOGRAPHS,
SUPP, VOL 7, PG 194, 1987:GRP 2B. NTP 6TH ANNUAL RPT ON CARCINS,
1991:ANTIC (ING 14)
Effects of Overexposure:HLTH HAZ:SKIN/EYE CONT:MAY CAUSE EYE
IRRIT/BURNING. RPTD/PRLNG LIQ CONT MAY CAUSE SKIN IRRIT
W/DISCOMFORT & DERM. INGS 1,5,10,13: RECURRENT OVEREXP MAY RSLT IN
LIVER & KIDNEY INJURY. ING 3:MAY POSS CA USE MODEST INITIAL IRRIT,
FOLLOWED IN HRS BY SEV SHORTNESS OF BREATH, REQUIRING PROMPT MED
ATTN. MAY CAUSE CNS(ING 15)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY & HAVE NAMES OF INGREDIENTS
AVAILABLE. DO NOT INDUCE VOMITING. INHAL:REMOVE TO FRESH AIR. IF
NOT BREATHING, GIVE ARTIFICIAL RESPIRATION, PREFERABLY MOUTH TO
MOUTH. IF BREATH ING DIFFICULTY PERSISTS OR OCCURS LATER, CONSULT
MD. EYE:IMMEDIATELY FLUSH W/PLENTY OF WATER FOR AT LEAST 15
MINUTES; CALL MD. SKIN:WASH W/SOAP & WATER. IF IRRITATION OCCURS
CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:<20F,<-7C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP. WATER MAY BE INEFT. WATER FROM FOG NOZZ MAY BE USED TO
COOL CLSD CNTNRS TO PVNT PRESS BUILD UP.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCL HCL &
PHOSGENE . CONTENTS UNDER PRESS. KEEP AT ROOM TEMP AS EXPOS TO
SUNLIGHT/OTHER HEAT MAY CAUSE CANS TO BURST, (SUPDAT)

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
PREVENT SKIN CONTACT & BREATHING OF VAPOR. CONFINE & REMOVE W/INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LBL PRECS. KEEP AWAY FROM
HEAT, SPKS & FLAME. DO NOT STORE >120F. DO NOT EXPOSE TO DIRECT
SUNLIGHT TO AVOID BURSTING. DO NOT PUNCTURE.
Other Precautions:DO NOT SAND, FLAME CUT, BRAZE/WELD DRY COATING W/OUT
NIOSH/MSHA APPRVD RESP/APPROP VENT. DO NOT SPRAY NEAR FIRE/OPEN
FLAME. NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICIN OF ARC
WELDING, OPEN FLAM ES/HOT SURFS. HEAT &/OR UV RADIA(ING 23)

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPS/MIST. WEAR APPROP, PROPERLY
FITTED NIOSH/MSHA APPROVED RESP DURING & AFTER APPLICATION UNLESS
AIR MONITORING DEMONSTRATES VAP/MIST LEVELS ARE BELOW APPLIC LIMS.
FOLLOW RESPIRATOR M FR'S DIRECTIONS FOR RESPIRATOR USE.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:EMER EYE WASH & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA.COVERALLS REC. PROTECTIVE CREAMS (WORK HYGENIC
PRAC)
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING & BEFORE EATING
& SMOKING.EYE PROTECTION: MAY BE USED FOR EASE OF CLEAN-UP, NOT FOR
PROT.
Supplemental Safety and Health
EXPLO HAZ:PROPELLING CONTENTS ACROSS AREA. ING 5 CAN CHEM REACT
W/ALUMINUM IN SPRAY EQUIP & OTHER DEVICES & CAUSE EXPLO HAZ. PRODS
CNTNG THIS SOLV SHOULD NEVER BE USED W/SPRAY EQUIP WHERE COATING
COME S IN CONT W/ALUMINUM. CONT W/ALUMINUM PARTS IN PRESSURIZABLE
FLUID SYS MAY CAUSE VIOLENT RXN.

Chemical Properties

Boiling Pt:B.P. Text:<0F,<-18C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.74
Evaporation Rate & Reference:FASTER THAN ETHER
Solubility in Water:MOD - APPRECIABLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:92

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:DO NOT STORE >120F.
Hazardous Decomposition Products:HCL, PHOSGENE . CO, CO*2, SMOKE OXIDES
OF HEAVY METALS REPORTED IN INGS.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL I/A/W FEDERAL, STATE &
LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.